USS Electrolyte Zinc and Zinc-Iron Alloy Coated Sheet is produced to meet the dimensional tolerances as shown in the following Tables (I - IV). If your application requires improved tolerances for performance reasons, please inquire.


Table I
Nominal Thickness
Electrogalvanized Sheet - Carbon and High Strength Steel Coils
Tolerances, Over and Under, for Specified Nominal Thickness
Specified Width,
inches
Over
.098 - .142
Over
.057 - .098
Over
.019* - .057
.014 - .019
24 - 72 .003 .003 .002 .001
Over 72 .004 .003 .002 .001
*Minimum thickness, .022 inch nominal for high strength steel.
Note: Thickness is measured at any point across the width not less than one inch from a side edge.


Table II
Minimal Thickness
Electrogalvanized Sheet - Carbon and High Strength Steel Coils
Tolerances, Over and Under, for Specified Nominal Thickness
Specified Width,
inches
Over
.098 - .142
Over
.057 - .098
Over
.019* - .057
.014 - .019
24 - 72 .006 .006 .004 .002
Over 72 .008 .006 .004 . . . .
*Minimum thickness, .020 inch for high strength steel.
Note: Thickness is measured at any point across the width not less than one inch from a side edge.

 
Table III
Width
Electrogalvanized Sheet - Carbon and High Strength Steel Coils
Specified Width, inches Tolerance Over Specified Width, Inches
No Tolerance Under
24 - 30 1/8
Over 30 - 48 3/16
Over 48 - 60 1/4
Over 60 - 72 5/16

 
Table IV
Flatness
Electrogalvanized Sheet
(Not Specified to Stretcher Leveled Standard of Flatness - Coils)
Thickness, inches Specified 
Width, In.
Flatness Tolerances*, Inches
Specified Yield Strength, min. ksi.
Nominal Minimum Under 45 45 - 50**
.046 & Thinner .044 & Thinner 24 - 36 3/8 3/4
Over 36 - 60 5/8 1 1/8
Over 60 - 72 7/8 1 1/2
Over .046 Over .044 24 - 36 1/4 3/4
Over 36 - 60 3/8 3/4
Over 60 - 72 5/8 1 1/8
Note 1 - Table IV does not apply when product is ordered full hard.
Note 2 - Table IV also applies to lengths cut from coils by our customer when adequate flattening measures are performed.

*Maximum deviation from a horizontal flat surface.
**Tolerances for high strength steel with specified minimum yield strength in excess of 50 ksi are subject to negotiation.

For the paint film, there are distinct requirements for attributes such as paint film thickness, paint hardness, primer thickness, paint gloss, etc. These are usually defined by mutual agreement among the customer, the paint company and, where applicable, the coil coater.


Typical Applications
Application Considerations
Fabrication Considerations
Tolerances