Tolerances for the steel substrate for prepainted sheet are covered by the tolerances specified for the unpainted metallic coated, steel sheet products. For example, for prepainted GALVALUME® steel sheet, the tolerances are the same as the tolerances for (unpainted) GALVALUME® steel sheet.

For the paint film, there are distinct requirements for attributes such as paint film thickness, paint hardness, primer thickness, paint gloss, etc. These are usually defined by mutual agreement among the customer, the paint company and the coil coater.

Hot-Dip Coated Sheet
U. S. Steel Hot-Dip Coated Sheet is produced to meet the dimensional tolerances as shown in the following Tables (I-IV). If your application requires improved tolerances for performance reasons, please inquire.

 
Table I
Nominal Thickness
Hot-Dip Coated Sheet Coils
Tolerances, Over and Under, for Specified Nominal Thickness
Specified Width,
inches
Over
.101 - .160 
Over
.075 - .101 
Over
.061 - .075 
.061 and
thinner
24 - 40 .006 .006 .003 .002
Over 40 - 60 .007 .006 .003 .002
Over 60 - 72 .007 .007 .003 .002

 
Table II
Minimum Thickness
Hot-Dip Coated Sheet Coils
Tolerances Over Specified Minimum Thickness
Specified Width,
inches
Over
.101 - .160 
Over
.075 - .101 
Over
.061 - .075 
.061 and
thinner
24 - 40 .012 .012 .006 .004
Over 40 - 60 .014 .012 .006 .004
Over 60 - 72 .014 .014 .006 .004

 
Table III
Width
Hot-Dip Coated Sheet 
Specified Width, inches Tolerance Over Specified
Width, Inches* 
Coils
24 - 30 1/8
Over 30 - 48 3/16
Over 48 - 60 1/4
Over 60 - 72 5/16
*No Tolerance Under

 
Table IV
Flatness
Hot-Dip Coated Sheet
(Not Specified to Stretcher Leveled Standard of Flatness - Coils) 
Specified Width, inches Specified Width,
In.
Flatness Tolerances*, In.
(Max. Deviation from a
horizontal flat surface). 
Nominal Minimum
05 & Thinner .048 & Thinner thru 36 3/8
Over 36 - 60 5/8
Over 60 - 72 7/8
Over .05 Over .048 thru 36 1/4
Over 36 - 60 3/8
Over 60 - 72 5/8
*Tolerances are subject to inquiry when the specified yield strength is in excess of 50 ksi or higher.

Camber Hot-Dip Coated Sheet Coils
Camber is the greatest deviation of a side from a straight line. The measurement is taken on the concave side with a straight edge. The camber tolerance for sheet in coils is 1/2 inch in any 20 feet of length. 