Sheet Products Home | U. S. Steel Home

 

HR Sheet | CR Sheet | Coated Sheet | Contacts | Glossary | Metric | MSDS | Search

  Appliance | Automotive | Construction | SCEA | USSI 


 

 


Sheet Products > Coated Sheet > USS ACRYLUME® Sheet >
Application Considerations

Properties | Coating Thickness | Surface Finish | Surface Treatment

Properties of the Base Steel
U. S. Steel ACRYLUME® steel sheet is available in the same steel designations as GALVALUME® steel sheet.
  • Commercial Steel (CS)
  • Forming Steel (FS)
  • Drawing Steel (DS)
  • High Temperature Steel (HTS)
  • Structural Steel (SS)

ASTM References

These designations are defined in ASTM Specification A792. The following two tables provide details about the strength levels and formability attributes for these designations as presented in ASTM A792. 

Typical Ranges of
Mechanical Properties*

 

Yield Strength

Elongation

R

N

Designation

 

ksi

MPa

 

in 2 in, %

Value

Value

CS Type B

35/60

245/410

 

>/= 20

A

A

FS

25/40

170/275

 

>/= 24

1.0/1.4

0.16/0.20

DS

20/35

140/240

 

>/= 30

1.3/1.7

0.18/0.22

HTS

30/65

205/450

 

>/= 15

A

A

*The typical mechanical property values presented in this table are nonmandatory. They are intended to provide the purchaser with as much information as possible to make an informed decision on the steel to be specified. Values outside of these ranges may occur.

 A - No typical properties have been established.

Structural Steel Mechanical
Property Requirements

Grade

Yield Strength
Minimum, ksi

Tensile Strength
Minimum, ksi

Elongation
in 2 inches, min
.

33

33

45

20

37

37

52

18

40

40

55

16

50 Class 1

50

65

12

50 Class 2

50

.....

12

80 A

80B

82

.....

Where an ellipsis (....) appears in the table, there is no requirement.

A - For sheet thicknesses of 0.028 and thinner, no tension test is required if the hardness result is Rockwell B 85 or greater.
B - As there is no discontinuous yield curve, the yield strength should be taken as the stress at 0.5% elongation under load or 0.2% offset.

Coating Thickness
The coating weight categories for the metallic coating are the same as those for the GALVALUME® steel sheet. The use of AZ55 or AZ50 should be decided on the same basis for regular GALVALUME® Steel sheet.

Surface Finish
The surface finish of ACRYLUME® steel sheet is basically unchanged from the typical appearance of the GALVALUME® coating since the acrylic film is clear. If anything, the appearance is somewhat satiny (less metallic gloss) especially when viewed at an oblique angle. The GALVALUME® steel sheet is typically not temper rolled prior to applying the acrylic film; thus, the normal small-spangle finish of GALVALUME® steel sheet is visible.

Surface Treatment
The acrylic coating on ACRYLUME® steel sheet does not require the use of any other surface treatment. The acrylic film offers the combined benefit of high resistance to storage staining and the lubricating effect of oil. The product is specifically not intended to be oiled when used for roofing, siding and decking. The absence of an oil provides improved worker safety.

ACRYLUME® steel sheet is only available with no additional surface treatments.

Corrosion Performance
The results of accelerated-corrosion tests show the superiority of ACRYLUME® steel sheet when compared with today's conventional chemically-treated GALVALUME®.

Wet Stack Test

  • Designed to simulate storage of sheets in either a coil form or as a stacked bundle at the jobsite.
  • Test samples stacked tightly in a bundle. Wetted between the individual panels every 2 days with deionized water.
  • Tested at 100°F for 750 hours. 

Hours in Test

ACRYLUME®

CT 1*

CT 2*

250

Light haze

Light surface spots

Dark black spots & edges

500

Light haze

Light surface patches

Heavy black patches

750

Light haze

Uniform surface darkening

Heavy, dark black patches

 

Water Immersion Test

  • Designed to stimulate ponding of water on a low slope roof
  • Samples immersed in deionized water.
  • Water temperature -- 100oF.
     

Hours in Test

ACRYLUME®

CT 1*

CT 2*

500

Slight dulling

Initial dark spots

Dark patches

1000

White patches with dark edges

Dark & light stains

Completely blackened

2000

White surface, dark edges

Dark stains

Completely blackened

Salt Spray Test

  • Tested per ASTM B117.
  • 5% salt solution.
  • 30-day test duration.
     

Time in Test

ACRYLUME®

CT 1*

CT 2*

250 Hours

No activity

White haze with small black spots

White haze with small black spots

500 Hours

Tiny spots, evidence of initial activity

White haze with black streaks

Uniform haze with black streaks

720 Hours

Small spots with local light streaks

Light haze with dark spots

Dark haze with dark spots

*CT 1 and CT 2 are two different conventional chemical treatments.

ACRYLUME® is a registered trademark of United States Steel.
GALVALUME® is a registered trademark of BIEC International, Inc.

 
 

U. S. Steel Corporate Links
Search
       Site Map       Contacts       What's New      Steel Links

 

Copyright 2005 United States Steel.  All rights reserved.
Site feedback.
Please see our Legal Notice for conditions regarding the use of this site 
and links provided to third-party web sites.
Trademarks and Ownership
Viewed best using IE v 4.0+ and Netscape v 4.0+ using 800 x 600 resolution.
Last Updated: